SolarEdge SE2200H - SE6000H inverters
Supported Devices

Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment |
---|---|---|---|
SolarEdge SE2200H | ✅ | ✅ | 🔶 (see warning below) |
SolarEdge SE3000H | |||
SolarEdge SE3500H | |||
SolarEdge SE3680H | |||
SolarEdge SE4000H | |||
SolarEdge SE5000H | |||
SolarEdge SE6000H |
CURTAILMENT IS ONLY SUPPORTED AFTER OBTAINING AN AGREEMENT WITH SOLAREDGE
If curtailment is not working on your SolarEdge device, it is probably not enabled by SolarEdge. Reach out to SolarEdge to enable control of your devices.
SolarEdge refuses to help customers with curtailment!
Wiring
For correct ethernet wiring: Follow the the guidelines for ethernet wiring.
Configuration
Activating Modbus TCP communication
In the menu, navigate to "Communication" -> "LAN Conf" -> "Modbus TCP", and activate Modbus TCP.
When Modbus TCP is activated, the following status screen will be displayed:
Modbus TCP: <status>
IP:192.168.1.210
Port:502